Sitemap | Contact | Imprint

NO-A nitric oxide delivery system

NO-A nitric oxide delivery system for inhaled nitric oxide (iNO) treatment
NO-A nitric oxide delivery sytem with unit holder for standard rail
NO-A nitric oxide delivery system with trolley for two gas cylinders
NO-A nitric oxide delivery system with trolley for three gas cylinders and maniNO manual gas blender for nitric oxide/oxygen

In June 2010 EKU Elektronik received the outpout orientated innovation award "Success" by the Investitions- und Strukturbank Rheinland-Pfalz (ISB) GmbH for the successful development of the NO-application device NO-A. EKU Elektronik received the award for the NO-A, a therapy device for the application of nitric oxide (NO) therapy gas in the ventilation flow of an intensive care patient in connection with different ventilators.

The inhaled nitric oxide (iNO) therapy shall reduce the clinical necessity of a left-to-right shunt and contribute to cardiac relief. In order to improve the oxygenation of ventilated patients nitric oxide (NO) is added to the respiratory gas. It is applied for the treatment of newborns, children and adults with pulmonary hypertension, oxygen deficiency, neonatal pulmonary failure, persistent pulmonary hypertension of neonates, pulmonary fibrosis, chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ARDS). Furthermore the device is used in cardiac surgery (cardiac valve diseases and cardiac transplantation) to treat an increased pulmonary pressure, as inhaled NO has a dilating effect on the blood vessels in the lung and therefore significantly improves the haemodynamics of the patient. Please refer to the relevant details listed in the information accompanying the finished medicinal product.

Features:

  • neonatal, paediatric or adult application
  • direct connection by ventilator interface
  • optional flow sensor for support of external ventilators of different brands
  • convenient design and comprehensive power supply for intrahospital transport (mains, 12V, battery)
  • dual cylinder management: operation with one or two cylinders with automatic flush and cylinder switching
  • wide-ranging cylinder compatibility (50 - 1000 ppm)
  • fail-safe dosing by secondary dosing system
  • wide dosing range by clocked dosing (13 µl/min - 17 l/min)
  • extended concentration range (0.1 - 99.9 ppm)
  • triggered or continuous dosing mode
  • dosing trend (1 h / 24 h)
  • timer (for non-responder-test or weaning)
  • integrated gas monitoring
  • optional oxygen monitoring
  • ambient air monitoring
  • interface connection to PDMS (e.g. via Philips VueLink/IntelliVue, EKU-PDMS and others)

For a detailed list of compatible ventilators please see here >>

For a short list of NO-A variations please see here >>

contact >>

Cooperation Partners

Distribution and service of the NO-A or of the different NO-A variations are exclusively performed by our authorised cooperation partners from the field of ventilation and gas supply such as:

NO-A for Getinge/MAQUET, Germany, Austria, Switzerland, BeNeLux
NO-A for Drägerwerk AG & Co. KGaA
NO-A for Messer Group
NO-A for SOL Group